← sparkquote.ai
INDIVIDUAL MCP TOOL
nec_ampacity
Allowable ampacity of one insulated conductor from NEC Table 310.
LIVE ENDPOINT
https://sparkquote.ai/mcp
Connect to this endpoint to inspect the live schema for nec_ampacity and invoke it with your own arguments.
Indexed input schema
{}Risk classification
Inferred read-only · medium confidence · heuristic, not a guarantee.
- No write-capable action terms were found; this is not proof that invocation has no side effects.
Parent server
CONNECT WITH APPROVAL
Client installation
Review this server and its permissions before adding it. Secret placeholders must be set locally.
Codex
~/.codex/config.toml
[mcp_servers.sparkquote]
url = "https://sparkquote.ai/mcp"
enabled = true
Claude Code
.mcp.json
{
"mcpServers": {
"sparkquote": {
"type": "http",
"url": "https://sparkquote.ai/mcp"
}
}
}
Claude Desktop
Settings → Connectors → Add custom connector
Name: sparkquote
Remote MCP URL: https://sparkquote.ai/mcp
Add this remote URL as a custom connector in Claude Desktop. Availability depends on the user plan and workspace policy.
Cursor
.cursor/mcp.json
{
"mcpServers": {
"sparkquote": {
"url": "https://sparkquote.ai/mcp"
}
}
}
Visual Studio Code
.vscode/mcp.json
Add to Visual Studio Code{
"servers": {
"sparkquote": {
"type": "http",
"url": "https://sparkquote.ai/mcp"
}
}
}
Generic MCP
Client-specific MCP configuration
{
"name": "sparkquote",
"transport": "streamable-http",
"url": "https://sparkquote.ai/mcp"
}
MCP Inspector
Run the official MCP Inspector locally and enter the indexed Streamable HTTP endpoint.
Related tools
wire_size— Minimum conductor size for a circuit: NEC Table 310.voltage_drop— Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).watts_to_amps— Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.conduit_fill— Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.box_fill— Minimum outlet box volume from NEC 314.load_calculator— Dwelling service load by the NEC 220.ohms_law— Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.panel_schedule— Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.