load_can_panel_handle

Answer 'can my existing panel handle a new load (EV charger, heat pump, ...)?' using the NEC 220.87 existing-dwelling method: 125% of the measured 12-month peak demand plus the new load, compared to the service rating.

intrysys.comnone authenticationAvailability not checked

LIVE ENDPOINT

https://www.intrysys.com/api/mcp

No auth detected

Connect to this endpoint to inspect the live schema for load_can_panel_handle and invoke it with your own arguments.

Indexed input schema

{}

Risk classification

Inferred read-only · medium confidence · heuristic, not a guarantee.

  • No write-capable action terms were found; this is not proof that invocation has no side effects.

Parent server

intrysys.com

CONNECT WITH APPROVAL

Client installation

Review this server and its permissions before adding it. Secret placeholders must be set locally.

Codex

~/.codex/config.toml

[mcp_servers.intry]
url = "https://www.intrysys.com/api/mcp"
enabled = true
Claude Code

.mcp.json

{
  "mcpServers": {
    "intry": {
      "type": "http",
      "url": "https://www.intrysys.com/api/mcp"
    }
  }
}
Claude Desktop

Settings → Connectors → Add custom connector

Name: intry
Remote MCP URL: https://www.intrysys.com/api/mcp

Add this remote URL as a custom connector in Claude Desktop. Availability depends on the user plan and workspace policy.

Cursor

.cursor/mcp.json

{
  "mcpServers": {
    "intry": {
      "url": "https://www.intrysys.com/api/mcp"
    }
  }
}
Visual Studio Code

.vscode/mcp.json

Add to Visual Studio Code
{
  "servers": {
    "intry": {
      "type": "http",
      "url": "https://www.intrysys.com/api/mcp"
    }
  }
}
Generic MCP

Client-specific MCP configuration

{
  "name": "intry",
  "transport": "streamable-http",
  "url": "https://www.intrysys.com/api/mcp"
}
MCP Inspector

Run the official MCP Inspector locally and enter the indexed Streamable HTTP endpoint.

Related tools

  • voltage_drop — Compute voltage drop for a copper or aluminum branch/feeder run using the NEC K-factor method (VD = 2·K·I·L / CM, K=12.9 Cu / 21.2 Al).
  • wire_size — Size a conductor for a load per NEC 310.16 with temperature correction (310.15(B)(1)), conduit-fill bundling (310.15(C)(1)), the 110.14(C) terminal cap, the 240.4(D) small-conductor limit, and the matching EGC (250.122).
  • ev_charger — Size a Level 2 EV charger circuit per NEC Article 625: conductor and breaker at 125% continuous, EGC, GFCI requirement, receptacle vs hardwire, and a rule-of-thumb panel-capacity check.
  • conduit_fill — Check conduit fill compliance per NEC Chapter 9 (53% one wire, 31% two, 40% three or more; 60% for a nipple ≤24").
  • box_fill — Compute junction/device box fill per NEC 314.16: conductor volume allowances, the device yoke (2×), clamps (1×), grounds (1×), and support fittings.
  • superheat_subcooling — Diagnose refrigerant charge from gauge readings: superheat = suction line temp minus saturation temp at suction pressure; subcooling = saturation temp at liquid pressure minus liquid line temp.
  • mca_mocp — From an HVAC nameplate MCA and MOCP (or from compressor RLA + fan FLA in RLA mode), return the minimum wire size (NEC 310.16, copper and aluminum), the breaker (largest standard 240.6(A) rating not exceeding MOCP per 440.22), the ground (250.122), and voltage drop.
  • line_set — Size the liquid and suction line set for R-454B, R-32, or R-410A by tonnage and length, and return a REUSE / FLUSH & REUSE / REPLACE verdict for an existing R-410A (or R-22) set, with the per-foot charge adjustment.