INDIVIDUAL MCP TOOL
elevacao_temperatura_painel
Elevação de temperatura do ar interno de um painel BT (IEC 60890) e verificação de aceitação (61439-1).
LIVE ENDPOINT
https://arc-flash-platform.onrender.com/mcp
Connect to this endpoint to inspect the live schema for elevacao_temperatura_painel and invoke it with your own arguments.
Indexed input schema
{}Risk classification
Inferred read-only · medium confidence · heuristic, not a guarantee.
- No write-capable action terms were found; this is not proof that invocation has no side effects.
Parent server
CONNECT WITH APPROVAL
Client installation
Review this server and its permissions before adding it. Secret placeholders must be set locally.
Codex
~/.codex/config.toml
[mcp_servers.arc-flash-platform-estudos-el-tricos]
url = "https://arc-flash-platform.onrender.com/mcp"
enabled = true
Claude Code
.mcp.json
{
"mcpServers": {
"arc-flash-platform-estudos-el-tricos": {
"type": "http",
"url": "https://arc-flash-platform.onrender.com/mcp"
}
}
}
Claude Desktop
Settings → Connectors → Add custom connector
Name: arc-flash-platform-estudos-el-tricos
Remote MCP URL: https://arc-flash-platform.onrender.com/mcp
Add this remote URL as a custom connector in Claude Desktop. Availability depends on the user plan and workspace policy.
Cursor
.cursor/mcp.json
{
"mcpServers": {
"arc-flash-platform-estudos-el-tricos": {
"url": "https://arc-flash-platform.onrender.com/mcp"
}
}
}
Visual Studio Code
.vscode/mcp.json
Add to Visual Studio Code{
"servers": {
"arc-flash-platform-estudos-el-tricos": {
"type": "http",
"url": "https://arc-flash-platform.onrender.com/mcp"
}
}
}
Generic MCP
Client-specific MCP configuration
{
"name": "arc-flash-platform-estudos-el-tricos",
"transport": "streamable-http",
"url": "https://arc-flash-platform.onrender.com/mcp"
}
MCP Inspector
Run the official MCP Inspector locally and enter the indexed Streamable HTTP endpoint.
Related tools
listar_ferramentas— Lista a prateleira de cálculos de engenharia elétrica e o tier de cada um.calcular_energia_incidente— Energia incidente (Ei, cal/cm²), LAS e categoria de EPI de um arco elétrico, pelo motor IEEE 1584:2018 / ABNT NBR 17227:2025 VALIDADO da plataforma (208 V– 15 kV).calcular_energia_incidente_hv— Energia incidente para sistemas > 15 kV — FORA do IEEE 1584:2018 / NBR 17227 (arco ao ar livre fase-terra).calcular_curto_circuito— Curto-circuito (IEC 60909) pelo motor da plataforma: Icc 3φ/2φ/fase-terra, X/R e pico.montar_rede— Monta uma REDE MULTIBARRA (concessionária → transformadores → cabos → quadros) e calcula o curto-circuito IEC 60909 em TODAS as barras de uma vez, pelo mesmo motor validado da plataforma (redução nodal do Anexo B: aceita alimentação radial, em paralelo e malha).tempo_de_atuacao— Tempo de atuação de um dispositivo de proteção à corrente de falta, pela curva composta 4-segmentos do motor da plataforma (IEC 60255-151 / IEEE C37.listar_dispositivos— Lista o catálogo de dispositivos (devices_db) para descobrir o `device_id` usado no modo catálogo de tempo_de_atuacao.gerar_memorial— Memorial assinável + etiqueta ANSI/NBR.