Design
midasiteurope.com
An MCP server that automates structural modeling tasks such as grouping elements by section/material and converting beams into plate or solid meshes, with undo support.
ENDPOINT 1
https://midasiteurope.com/mcp
MCP server metadata
- Name
- civil-nx
- Version
- 0.8.1
Tools that build, check and report on a MIDAS CIVIL NX model through the engines of the MIDAS IT Europe plugins. Each tool runs the same code as its plugin, so the plugin's rules and checks — verified against live CIVIL NX — apply. How to work: - Start with civil_status: it confirms CIVIL NX is connected and summarises the open model (units, groups, load cases, stages). Read only what you need with the read tools before proposing inputs. - Tools of kind "calc" need no model; "read" tools only read it; "write" tools change it; "job" tools may run long. - On the website, every apply (and every long job) runs in the background: the call returns { jobId, status: "queued" } at once. Poll job_status with that jobId every few seconds until status is "done" (the tool's result is in result) or "failed" (the reason is in error). Do not call the apply again while it runs. - Every write tool previews by default (apply omitted or false) and writes nothing. Show the user the preview, get their go-ahead, then call again with the same inputs, apply: true and confirmPlanHash set to the preview's planHash. If the model changed in between, the apply refuses rather than writing something the user did not see. - Never set options marked DESTRUCTIVE (replaceExisting, codeChange, unitSwitch, …) without the user agreeing to what the preview says they do. - Every apply is recorded; undo_run lists the recorded runs and reverses one (preview first, then apply: true). Undo in reverse order (later work before the model it sits on). - On the website, tools that read or write the model need the user's personal token from midasiteurope.com/llm (a free account); calculation tools work without one. There is no limit on how many writes an account may apply. - Files (IFC, DXF, XLSX, PDF) come back as a download link, never inline. - A sketch or photo of a cross-section becomes a CIVIL NX section through Section Designer: section_preview (look at the drawing it returns and compare it with the sketch; ask about any dimension the sketch does not give) → section_properties → section_write. - New spans, support skews, a new alignment or new deck levels for a bridge model that already exists go through Bridge Reshaper: bridge_reshape_read → bridge_reshape (look at the plan drawing it returns: grey as it is, blue proposed) → apply with the user's go-ahead → undo_run if needed. - To check a model for mistakes ("is anything wrong with my model?", before a design check or a report), run model_health_check: it reports by area (geometry, properties, units, boundaries, loads, moving loads, stages, combinations, groups, tendons, results) with red/amber/green. It catches typing slips (creep/shrinkage fck in MPa typed into a kN/m² box, humidity as a fraction, sizes in mm in a metre model, tendon area/strength/jacking-stress slips), tendon cover and friction loss, construction-stage set-up, and moving-load mistakes against EN 1991-2 and CS 454 (lane widths, wheel spacing — BS stores a third —, lanes off the deck or overlapping, missing lanes/vehicles, the Eurocode ψ setting against frequent/characteristic cases, α factors); on an analysed model it also checks reactions against the applied loads, self weight against the element volumes, displacements, and each construction stage. Explain each failed check from its criterion and ids; do not change the model unless the user asks. - Which load cases make up a combination's result: combination_tree → combination_contributions (every item is checked against CIVIL NX's own value). - Prestressing tendons for a concrete girder go through Tendon Designer: tendon_design designs new tendons, or reads the model's own (mode improve) and checks them to EN 1992-1-1; go through any failed check with the user (autoResolve tries the smallest change that clears it) and confirm a concrete grade it says was not read. Then tendon_write (preview, then apply; name the construction stage each tendon group is stressed in when the model has stages), and undo_run to take them out again. - An EN 1992 (Eurocode) check of concrete beam, column, pier or pile sections — reinforced, or prestressed / precast girder + deck slab — goes through the Eurocode Section Checker: ec2_describe_section (look at the drawing it returns with the bars and tendons placed and compare it with the user's drawing; ask about cover, links or anything the drawing does not show) → ec2_section_check → ec2_export_calc_sheet for the Excel calculation sheet. For a prestressed section, agree with the user which load cases are the girder self-weight and which act on the precast girder alone (stages). CS 455 assessments go through the cs455_* tools instead. - For how-to questions, what a CIVIL NX input means, or the JSON of a MIDAS API table, search the MIDAS manuals with midas_docs_search and read the article with midas_docs_read before answering from memory; give the user the article's link. - Supports, point springs, beam end releases, self-weight, nodal loads, beam UDLs, plate pressures and element temperatures go through civil_loads_supports in ONE call: name where (structure group, id ranges, a line, a box, a coordinate, pick xmin/xmax for girder ends) and what, in kN and m — no table lookup, no reading nodes or elements, no rows. Check the totals per load case in its preview with the user. Hand-picked combinations ("ULS = 1.35 SW + 1.5 LL"): civil_combinations_quick. Taking loads, supports or load cases out: civil_remove_loads (it keeps the other cases' loads on the same elements). - When no tool fits a model change, use civil_write_tables rather than telling the user it cannot be done; never try to drive the CIVIL NX window instead. - Prefer a plugin tool where one does the job. For anything else — building a model from scratch, or a change no plugin makes — use civil_write_tables: look up each table's fields in the API manual first (midas_docs_read) and valid names in midas_library (material standards and grades, section shapes and their dimension order, element and support rows), write in dependency order (materials and sections, nodes, elements, supports, load cases, loads), preview, and apply only with the user's go-ahead. Then civil_save_model (a new model needs a path) and civil_run_analysis before reading results.
Known tools 93
analysis_diagnoseUse when the analysis stops or warns ("DOF may be singular", "error norm is infinite / NaN", convergence not reached, run-time errors): pass the message text.
Potential side effectsauto_structure_groupsUse to group elements automatically by section, material or both.
Inferred read-onlyb2p_surveyUse before b2p_convert, to see which beams and sections can become a plate or solid mesh.
Inferred read-onlyb2p_convertUse to replace beam elements with a plate or solid mesh of their real cross-section (a detailed local model).
Inferred read-onlybridge_reshape_readUse before bridge_reshape, to see the existing bridge's spans, skews, alignment and levels.
Inferred read-onlybridge_reshapeUse to change the spans, support skews, alignment or deck levels of a bridge that is already in the model.
Inferred read-onlybridge_thermal_calcUse for code temperature values of a bridge (EN 1991-1-5, CS 454, BS 5400-2) without touching the model.
Inferred read-onlybridge_thermal_readUse before bridge_thermal_apply, to find the deck and its sections.
Inferred read-onlybridge_thermal_applyUse to write code-derived bridge temperature load cases (EC1T_…) on the deck.
Potential side effectsbridge_thermal_removeUse to delete every EC1T_ thermal load case, whichever run or window wrote it.
Potential side effectsconcurrent_forces_setupConcurrent forces, step 1: use before concurrent_forces to list the items, effects and load states the model offers.
Inferred read-onlyconcurrent_forcesUse for the forces that act together with the extreme of ONE effect (e.
Inferred read-onlyconcurrent_forces_probeUse only to diagnose why concurrent_forces finds no results for a source; not a result reader.
Inferred read-onlycs454_lane_layoutUse to lay out CS 454 notional lanes on a carriageway width, with no model.
Inferred read-onlycs454_moving_loadsUse for UK CS 454 assessment live loading (lanes, vehicles, moving-load cases).
Inferred read-onlycs455_assessUse for CS 455 (UK assessment) ULS of RC beam, column, pier or pile sections.
Inferred read-onlycs455_export_calc_sheetUse for the CS 455 Excel calculation sheet of one element end.
Inferred read-onlycs_stage_summaryUse to list the construction stages already in the model (durations, groups activated).
Inferred read-onlymidas_docs_searchUse for how-to questions, what a CIVIL NX input means, or a MIDAS API table's fields.
Inferred read-onlyec_lane_layoutUse to lay out EN 1991-2 notional lanes on a carriageway width, with no model.
Inferred read-onlyec_moving_loadsUse for EN 1991-2 traffic loading (lanes, vehicles, moving-load cases).
Inferred read-onlyec_wind_bridgeUse for bridge deck wind values (EN 1991-1-4 or CS 454) without touching the model.
Inferred read-onlyec_wind_export_calc_sheetUse for the wind hand calculation as an Excel workbook (EN 1991-1-4 or CS 454) for a checker.
Inferred read-onlyec_wind_removeUse to delete the wind load cases the Wind Load Calculator wrote (EC1W_, C454W_); it is also the undo of ec_wind_apply.
Potential side effectsskew_grillageUse to create a new bridge deck (beam grillage or plate mesh) from spans, widths and skew.
Potential side effectscombination_treeUse to list the model's combinations, or show one's tree of cases and factors.
Inferred read-onlycombination_contributionsUse to find which load cases make up a combination's result at given items.
Inferred read-onlymidas_libraryUse for valid names when writing tables: material standards and grades, section shapes and their dimension order, element and support rows.
Inferred read-onlymodel_report_imagesUse before model_report_export, to pick the pictures for the report.
Inferred read-onlymodel_bridge_summaryUse before model_to_ifc or model_to_dxf, to see what the exporter finds.
Inferred read-onlycreate_nodesUse to create many nodes from coordinates, with the plugin's checks.
Potential side effectspd6694_route_aUse for PD 6694-1 integral abutment earth pressures by the limit-equilibrium route, with no model.
Inferred read-onlypd6694_route_a_writeUse after pd6694_route_a, to write its pressures on the abutment walls.
Potential side effectspd6694_route_a_removeUse to remove the Route A cases; it is also the undo of pd6694_route_a_write.
Potential side effectspoint_to_patch_dispersalUse for one wheel or point load's dispersal patch, with no model.
Inferred read-onlypoint_to_patch_applyUse to turn the model's point loads into dispersed patch loads.
Inferred read-onlycivil_loads_supportsUse for any support, spring, release, self-weight, nodal load, UDL, pressure or temperature you can state directly.
Inferred read-onlyslab_capacities_from_barsUse to turn a slab's bar arrangement into capacities for slab_assess, with no model.
Inferred read-onlyresult_table_catalogUse to find a result table's id before preview_result_table or export_result_tables.
Inferred read-onlypreview_result_tableUse to look at analysis results (or a model table) row by row.
Inferred read-onlysection_writeUse to write a designed section into the model, after section_preview.
Potential side effectsstage_groupsUse to make structure groups by position (slices, segments) for staging.
Inferred read-onlystress_element_loadsUse before stress_profile, to see what results each beam element has.
Inferred read-onlysls_stress_checkUse for SLS stress limits over many elements (EN 1992-2, EN 1993-2).
Inferred read-onlytendon_designUse to design, or check, the prestressing tendons of a concrete girder.
Inferred read-onlyec2_section_checkUse for EN 1992 checks of RC or prestressed beam, column, pier or pile sections.
Inferred read-onlyundo_runUse to reverse any change a tool made to the model (list the recorded runs, preview, then apply).
Inferred read-onlyCONNECT WITH APPROVAL
Client installation
Review this server and its permissions before adding it. Secret placeholders must be set locally.
Codex
~/.codex/config.toml
[mcp_servers.civil-nx]
url = "https://midasiteurope.com/mcp"
enabled = true
Claude Code
.mcp.json
{
"mcpServers": {
"civil-nx": {
"type": "http",
"url": "https://midasiteurope.com/mcp"
}
}
}
Claude Desktop
Settings → Connectors → Add custom connector
Name: civil-nx
Remote MCP URL: https://midasiteurope.com/mcp
Add this remote URL as a custom connector in Claude Desktop. Availability depends on the user plan and workspace policy.
Cursor
.cursor/mcp.json
{
"mcpServers": {
"civil-nx": {
"url": "https://midasiteurope.com/mcp"
}
}
}
Visual Studio Code
.vscode/mcp.json
Add to Visual Studio Code{
"servers": {
"civil-nx": {
"type": "http",
"url": "https://midasiteurope.com/mcp"
}
}
}
Generic MCP
Client-specific MCP configuration
{
"name": "civil-nx",
"transport": "streamable-http",
"url": "https://midasiteurope.com/mcp"
}
MCP Inspector
Run the official MCP Inspector locally and enter the indexed Streamable HTTP endpoint.
TRUST AND VERIFICATION EVIDENCE
Loading Trust v2 evidence…
Checking the associated registrable domain. The BuiltWith key remains server-side.
Evidence is source-attributed and does not guarantee that a third-party server is safe. Risk labels are conservative metadata heuristics.