elec-mate.com
Provides lookups and calculations for UK electrical standards (BS 7671) for professionals.
ENDPOINT 1
https://www.elec-mate.com/api/public/v1/mcp
Known tools 22
bs7671_lookup_regulationFetch the full text of a specific BS 7671:2018+A4:2026 regulation by its number (e.g.
bs7671_lookup_tableFetch a BS 7671:2018+A4:2026 table by number (e.g.
bs7671_searchSearch Elec-Mate's canonical UK electrical content store — 46k+ verified chunks across BS 7671:2018+A4:2026 + IET Guidance Note 3 (9th Ed) + IET On-Site Guide (9th Ed).
calculate_zs_maxCalculate the maximum permitted earth fault loop impedance (Zs) for an MCB per BS 7671:2018+A4:2026 Reg 411.4.4.
calculate_disconnection_timeMaximum permitted disconnection time per BS 7671:2018+A4:2026 Table 41.1.
calculate_voltage_dropVoltage drop calculation per BS 7671:2018+A4:2026 Appendix 4 Tables 4D1A/4D1B.
pwi_install_timeTypical labour time for a UK electrical job — aggregated from Elec-Mate's verified UK electrical data dataset (199k+ UK electrical records).
pwi_common_defectsMost-frequent defects an inspector finds in a category — sourced from Elec-Mate's verified UK electrical data.
pwi_eicr_codesEICR observation codes (C1/C2/C3/FI) typically applied to faults in this category.
pwi_troubleshootingStep-by-step troubleshooting + diagnostic test sequence for a category, aggregated from UK fault-finding records.
pwi_materialsMaterials + tools typically required for a UK electrical job in this category.
pricing_jobVerified UK pricing for an electrical job — avg/min/max GBP by region.
eicr_code_explainedReturns the IET Best Practice Guide 4 definition of an EICR classification code: meaning, action required, EICR outcome impact, typical examples.
bs7671_lookup_sectionReturns every BS 7671:2018+A4:2026 regulation in a specific section (e.g.
pwi_inspection_checklistVisual inspection points + structured inspection checklist for an EICR or initial verification, aggregated from real UK inspection records.
pwi_installation_procedureInstallation method + fixing intervals + cable routes + termination methods + test procedures for a UK electrical job — aggregated from real UK installation records.
pwi_semantic_searchFree-text hybrid search across 199k+ verified UK electrical install/maintenance records (Elec-Mate's labour-intelligence corpus).
pwi_job_packComplete job profile in one call — aggregated across the top matching practical-work records.
calculate_earth_rod_resistanceMaximum permitted earth electrode resistance (Ra) for a TT system per BS 7671 Reg 411.5.3 (Ra × IΔn ≤ 50V).
notifiable_work_checkReturns whether the electrical work is notifiable under Part P of the Building Regulations (England).
certificate_requiredReturns which BS 7671 certificate is required for a category of electrical work in the UK (EIC, Minor Works, EICR, PAT, etc.).
calculate_cable_sizeRecommends a minimum cable size (mm² copper twin & earth, 70°C thermoplastic) per BS 7671:2018+A4:2026 Appendix 4.